Hydrogen peroxide is a promising substitute for fossil fuels because it produces non-hazardous by-products. In this work, a glassy carbon GC was anodized in sulphuric acid at +1.8 V to prepare the working electrode. It was utilized to investigate the oxygen reduction reaction (ORR) in a basic medium containing 0.1 M NaOH as a supporting electrolyte. The objective of this investigation was to synthesize hydrogen peroxide. X-ray photoelectron spectroscopy (XPS), electrochemical impedance spectroscopy (EIS), linear polarization, cyclic voltammetry (CV), and rotating disk electrode voltammetry (RDE) were performed for characterization and investigation of the catalytic properties. The RDE analysis confirmed that oxygen reduction reactions followed two electrons’ process at an activated GC electrode. Hence, the prepared electrode generated hydrogen peroxide from molecular oxygen at a potential of around −0.35 V vs. Ag/AgCl (sat. KCl), significantly lower than the pristine GC surface. The transfer coefficient, standard reduction potential, and standard rate constant were estimated to be 0.75, −0.27 V, and 9.5 × 10−3 cm s−1, resectively.